ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line
All aluminium conductor, polyethylene or cross linked polyeth- ylene insulation, concentric strand AAC, ACSR, or 6201 alloy neu- tral messenger.
Description |
Phase conductor |
Bare |
Approx.Overall |
|||
NO of Standing& |
XLPE |
NO of Stranding& |
Diameter |
Weight |
||
AL |
Steel |
|||||
1×10mm²+10mm² |
7 /1.35 |
1.0 |
6/1.35 |
1/1.35 |
10.30 |
858 |
1×16mm²+16mm² |
7/1.70 |
1.2 |
6/1.70 |
1/1.70 |
12.84 |
133.7 |
1×25mm²+25mm² |
7/2.22 |
1.2 |
62.22 |
12.22 |
15.04 |
215.8 |
1×35mm²+35mm² |
7/2.59 |
1.4 |
62.59 |
12.59 |
17.8B |
294.0 |
1×50mm²+50mm² |
7/3.10 |
1.4 |
63.10 |
13.10 |
19.68 |
410.2 |
1×70mm²+50mm² |
19/2.22 |
1.4 |
6/3.10 |
1/3.10 |
21.38 |
574.3 |
1×95mm²+50mm² |
19/2.59 |
1.4 |
6/3.10 |
13.10 |
22.98 |
704.5 |
2×10mm²+10mm² |
7/1.35 |
1.0 |
6/1.35 |
1/1.35 |
12.30 |
120.7 |
2×16mm²+16mm² |
7 /1.70 |
1.2 |
6/1.70 |
1/1.70 |
15.24 |
133.7 |
2×25mm²+25mm² |
7/2.22 |
12 |
6/2.22 |
172.22 |
17.44 |
310.2 |
2×35mm²+35mm² |
7/ 2.59 |
1.4 |
6/2.59 |
172.59 |
20.28 |
422.5 |
2×50mm²+50mm² |
7/3.10 |
1.4 |
6/3.10 |
1/3.10 |
22.48 |
594.2 |
2×70mm²+50mm² |
19/2.22 |
1.4 |
6/3.10 |
1/3.10 |
25.88 |
964.5 |
2×95mm²+50mm² |
19/2.59 |
1.4 |
6/3.10 |
1/3.10 |
2908 |
1224.9 |
3×10mm²+10mm² |
7/1.35 |
1.0 |
6/1.35 |
1/1.35 |
14.76 |
187.6 |
3×16mm²+16mm² |
7/1.70 |
1.2 |
6/1.70 |
1/1.70 |
18.28 |
290.4 |
3×25mm²+25mm² |
7/2.22 |
1.2 |
62.22 |
12.22 |
20.92 |
458.6 |
3×35mm²+35mm² |
7/2.59 |
1.4 |
62.59 |
12.59 |
24.33 |
625.0 |
3×50mm²+50mm² |
7/3.10 |
1.4 |
63.10 |
1/3.10 |
26.97 |
862.3 |
3×70mm²+50mm² |
19/2.22 |
1.4 |
6/3.10 |
1/3.10 |
31.05 |
1354.7 |
3×95mm²+50mm² |
19/2.59 |
1.4 |
6/3.10 |
1/3.10 |
34.89 |
1745.3 |
Q: What is the full form of ACSR in ACSR Self-Supporting ABC Cable?
A: ACSR stands for Aluminum Conductor Steel Reinforced, indicating a cable with aluminum conductors and a steel core for mechanical strength
Q: What is the maximum voltage rating for ACSR Self-Supporting ABC Cable?
A: Typically rated for 33 kV to 230 kV, depending on insulation and design standards
Q: How does the steel core enhance the performance of ACSR cables?
A: The steel core provides high tensile strength, allowing longer spans between supports and resistance to wind/ice loads
Q: What materials are used in the insulation of Self-Supporting ABC Cables?
A: Common insulators include cross-linked polyethylene (XLPE) or PVC, with ABC referring to All-Black insulation for UV resistance
Q: Can ACSR Self-Supporting ABC Cables be used in coastal areas?
A: Yes, but galvanized steel cores and corrosion-resistant coatings are recommended for saltwater environments
Q: What are the typical applications of these cables?
A: Used in overhead power transmission, rural electrification, and industrial grids due to their durability and cost-effectiveness
Q: How do you calculate the sag of ACSR cables during installation?
A: Sag depends on span length, tension, and temperature, with formulas provided in IEEE or IEC standards
Q: What maintenance is required for ACSR Self-Supporting ABC Cables?
A: Regular visual inspections for corrosion, bird damage, and insulator contamination are essential
Q: Can these cables be buried underground?
A: Not typically designed for burial; use underground cables like XLPE for such applications